• DocumentCode
    748656
  • Title

    Advance validation of radiation hardness and reliability of lasers for CMS optical links

  • Author

    Macias, R. ; Axer, M. ; Dris, S. ; Gill, K. ; Grabit, R. ; Noah, E. ; Troska, J. ; Vasey, F.

  • Author_Institution
    CERN, Geneva, Switzerland
  • Volume
    52
  • Issue
    5
  • fYear
    2005
  • Firstpage
    1488
  • Lastpage
    1496
  • Abstract
    The production of laser transmitters for 60000 optical links is ongoing for the CMS Experiment at CERN. A series of advance validation tests (AVTs) that assure the radiation hardness and reliability has been performed on 390 edge-emitting 1310 nm lasers taken from 13 different starting wafers, before the laser die have been assembled into final transmitters. The AVT also offered a first opportunity to characterize, with good statistics, the effects of radiation damage, annealing and accelerated aging, using a large number of laser samples.
  • Keywords
    ageing; annealing; nuclear electronics; optical links; position sensitive particle detectors; radiation hardening (electronics); reliability; CERN; CMS experiment; accelerated aging; advance validation tests; annealing; laser die; laser transmitters; optical links; radiation damage; radiation hardness; reliability; Accelerated aging; Annealing; Assembly; Collision mitigation; Optical fiber communication; Optical transmitters; Performance evaluation; Production; Statistics; Testing; CMS optical links; lasers; radiation hardness assurance; reliability;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.2005.855812
  • Filename
    1546448