DocumentCode
748929
Title
A compact VLSI dc restorer for multichannel X-γ ray detectors
Author
Pullia, A. ; Maiocchi, D. ; Bertuccio, G. ; Caccia, S.
Author_Institution
Dept. of Phys., Univ. of Milano, Italy
Volume
52
Issue
5
fYear
2005
Firstpage
1643
Lastpage
1646
Abstract
We present a compact, fully integrated, low power baseline restorer for radiation detector readout ASICs. The proposed circuit has been designed, simulated, and layed out using a 0.35 μm CMOS technology. It features an area occupancy of 90×100 μm2 and a power consumption of 90 μW for 3.3V power supplies, which makes it suitable for highly packed multichannel detector readouts. In the paper the principle of operation of the circuit as well as the results of the simulations are discussed.
Keywords
CMOS integrated circuits; VLSI; X-ray detection; application specific integrated circuits; gamma-ray detection; nuclear electronics; readout electronics; 0.35 micron; 3.3 V; 90 muW; CMOS technology; VLSI dc restorer; X-ray detector; gamma-ray detector; highly packed multichannel detector readouts; low power baseline restorer; power consumption; radiation detector readout ASIC; CMOS technology; Circuit simulation; Gamma ray detection; Gamma ray detectors; Radiation detectors; Resistors; Signal restoration; Switches; Very large scale integration; Voltage; Baseline restorer; dc restorer; integrated circuit; shaper amplifier; spectroscopy amplifier;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.2005.856762
Filename
1546477
Link To Document