• DocumentCode
    754014
  • Title

    Validation of mechanical governor performance and models using an improved system for driving ballhead motors

  • Author

    Age, J.C. ; Girgis, George K.

  • Author_Institution
    Bur. of Reclamation, Denver, CO, USA
  • Volume
    10
  • Issue
    1
  • fYear
    1995
  • fDate
    3/1/1995 12:00:00 AM
  • Firstpage
    156
  • Lastpage
    161
  • Abstract
    The Bureau of Reclamation has developed new equipment and procedures for testing mechanical-hydraulic governors for hydroelectric generators. The test equipment generates a three-phase voltage that will drive the governor ballhead motor at variable speed. Most traditional governor tests can be completed with the generating unit unwatered using this equipment. In addition, frequency response testing and other detailed analytical tests can be performed to validate governor models using this equipment
  • Keywords
    digital simulation; electric machine analysis computing; electric motors; frequency response; hydroelectric generators; machine control; machine testing; mechanical control equipment; simulation; Bureau of Reclamation; PMG simulator; ballhead motors; frequency response testing; hydroelectric generators; mechanical governor performance; mechanical-hydraulic governors; three-phase voltage; variable speed; Counting circuits; Frequency conversion; Hydroelectric power generation; Power amplifiers; Power generation; Power system modeling; Signal generators; Switches; System testing; Voltage;