DocumentCode
754014
Title
Validation of mechanical governor performance and models using an improved system for driving ballhead motors
Author
Age, J.C. ; Girgis, George K.
Author_Institution
Bur. of Reclamation, Denver, CO, USA
Volume
10
Issue
1
fYear
1995
fDate
3/1/1995 12:00:00 AM
Firstpage
156
Lastpage
161
Abstract
The Bureau of Reclamation has developed new equipment and procedures for testing mechanical-hydraulic governors for hydroelectric generators. The test equipment generates a three-phase voltage that will drive the governor ballhead motor at variable speed. Most traditional governor tests can be completed with the generating unit unwatered using this equipment. In addition, frequency response testing and other detailed analytical tests can be performed to validate governor models using this equipment
Keywords
digital simulation; electric machine analysis computing; electric motors; frequency response; hydroelectric generators; machine control; machine testing; mechanical control equipment; simulation; Bureau of Reclamation; PMG simulator; ballhead motors; frequency response testing; hydroelectric generators; mechanical governor performance; mechanical-hydraulic governors; three-phase voltage; variable speed; Counting circuits; Frequency conversion; Hydroelectric power generation; Power amplifiers; Power generation; Power system modeling; Signal generators; Switches; System testing; Voltage;
fLanguage
English
Journal_Title
Energy Conversion, IEEE Transactions on
Publisher
ieee
ISSN
0885-8969
Type
jour
DOI
10.1109/60.372581
Filename
372581
Link To Document