DocumentCode
755331
Title
Analysis and Field Results for No. 1 ESS Networks
Author
Farel, Richard A.
Author_Institution
Bell Labs., Holmdel, NJ
Volume
27
Issue
1
fYear
1979
fDate
1/1/1979 12:00:00 AM
Firstpage
10
Lastpage
15
Abstract
Using the Network Analytical Simulator (NEASIM) computer program, various parameters affecting line-to-line junctor overflow in No. 1 ESS switching networks are studied. These include the line-link network load, the line-to-line junctor load, the number and type of line-to-line junctors, and the line concentration ratio and concentrator type. Based on the results of these simulations, a family of simple fitted blocking formulas, accurate over a wide range of network and junctor loads, are developed. Comparison with field data recently obtained from nine No. 1 ESS offices indicates very good agreement between the NEASIM results and measured performance.
Keywords
Telephone switching; Analytical models; Central office; Computational modeling; Computer networks; Computer simulation; Electronic switching systems; Helium; Performance evaluation; Solids; Testing;
fLanguage
English
Journal_Title
Communications, IEEE Transactions on
Publisher
ieee
ISSN
0090-6778
Type
jour
DOI
10.1109/TCOM.1979.1094278
Filename
1094278
Link To Document