DocumentCode
758491
Title
Architecture tradeoffs in high-density microstimulators for retinal prosthesis
Author
Sivaprakasam, Mohanasankar ; Liu, Wentai ; Wang, Guoxing ; Weiland, James D. ; Humayun, Mark S.
Author_Institution
Dept. of Electr. Eng., Univ. of California, Santa Cruz, CA, USA
Volume
52
Issue
12
fYear
2005
Firstpage
2629
Lastpage
2641
Abstract
Electrical stimulation of the retinal layer inside the eye has been identified as a form of visual prosthesis to restore lost vision in blind patients affected by retinitis pigmentosa and age-related macular degeneration, through several studies and experiments. While initial clinical experiments using retinal prosthesis have resulted in visual perception in humans, psychophysical tests and simulations suggest that a high-density retinal prosthesis is required to restore vision to a level of reading and mobility. In the implanted prosthetic device, the microstimulator is functionally the closest to the tissue, delivering the electrical stimulation. Choosing the suitable architecture of the microstimulator requires the knowledge of the available choices and the tradeoffs associated with each of them. This paper presents the different architectures of microstimulator for high-density retinal prosthesis considering both the biomedical and circuit perspectives. The choices for the key aspects of the microstimulator-location of the chip in the eye, electrode configuration, method of stimulation, demultiplexing, stimulation sequence, and communication protocol-are discussed along with the associated tradeoffs for each of them. One of the architectures is used in a prototype microstimulator for an implantable epi-retinal prosthetic device to be used in clinical trials. The chip consists of 60 independently programmable output drivers for delivering electrical stimulus and digital controller for managing run-time and configuration data. The circuit details of the chip fabricated in 1.2-μm CMOS technology and its measurement results are presented.
Keywords
CMOS integrated circuits; biomedical electronics; driver circuits; eye; neuromuscular stimulation; prosthetics; sensory aids; 1.2 micron; CMOS technology; age-related macular degeneration; communication protocol; digital controller; electrode configuration; functional electrical stimulation; high-density microstimulator; implantable device; implantable epi-retinal prosthetic device; implanted prosthetic device; independently programmable output drivers; psychophysical test; retinal layer; retinal prosthesis; retinitis pigmentosa; vision restoration; visual perception; visual prosthesis; CMOS technology; Circuits; Electrical stimulation; Humans; Pigmentation; Prosthetics; Psychology; Retina; Visual perception; Visual prosthesis; Biomedical; functional electrical stimulation (FES); implantable devices; microstimulator; retinal prosthesis;
fLanguage
English
Journal_Title
Circuits and Systems I: Regular Papers, IEEE Transactions on
Publisher
ieee
ISSN
1549-8328
Type
jour
DOI
10.1109/TCSI.2005.857554
Filename
1556771
Link To Document