Abstract
New methods for monitoring via and line voiding in metal interconnect structures are described. A focused laser beam injects heat into a structure such as a line or via chain, which may have width considerably smaller than the spot size. Conduction of heat, and therefore temperature under the spot, is a function of via or line integrity. Probing the temperature using laser reflection provides a direct nondestructive measure of via continuity or line voiding.
Keywords
copper; integrated circuit interconnections; integrated circuit measurement; measurement by laser beam; voids (solid); Cu; damascene Cu lines; focused laser beam; laser reflection; line integrity; line voiding monitoring; metal illumination; metal interconnect structures; temperature probing; via integrity; via voiding monitoring; voiding measurements; Circuit faults; Copper; Dielectrics; Fluorescence; Focusing; Integrated circuit interconnections; Lighting; Scanning electron microscopy; Temperature; Testing;