DocumentCode
765158
Title
High energy cable development for pulsed power applications
Author
Jamison, Keith A. ; Stearns, Ronald E. ; Klug, Reja B. ; Ford, Richard D.
Author_Institution
Sci. Applications Int. Corp., Shalimar, FL, USA
Volume
27
Issue
1
fYear
1991
fDate
1/1/1991 12:00:00 AM
Firstpage
374
Lastpage
379
Abstract
A cable design is presented, along with the development of terminal connectors. The characterization tests of a first run sample of high-power cable are described. The cable end connectors described have proven ability to conduct large current pulses. In fact, a safety factor of nearly two has been demonstrated for the intended operational levels for the cables. The cable resistance has been shown to approach the DC resistance value 440 μΩ/m in a 1 ms pulse duration. For shorter times, such as the 100 μs point, the cable resistance is higher, approximately 500 μΩ/m. The cable inductance is on the order of 190 nH/m for low-frequency operation and about 15% lower for short times as short as 50 μs
Keywords
electric connectors; power cables; pulsed power technology; safety; DC resistance; cable inductance; end connectors; high-power cable; pulsed power; safety factor; terminal connectors; Coaxial cables; Conductors; Connectors; Laboratories; Magnetic field measurement; Power cables; Power supplies; Switches; Testing; Voltage;
fLanguage
English
Journal_Title
Magnetics, IEEE Transactions on
Publisher
ieee
ISSN
0018-9464
Type
jour
DOI
10.1109/20.101060
Filename
101060
Link To Document