• DocumentCode
    765158
  • Title

    High energy cable development for pulsed power applications

  • Author

    Jamison, Keith A. ; Stearns, Ronald E. ; Klug, Reja B. ; Ford, Richard D.

  • Author_Institution
    Sci. Applications Int. Corp., Shalimar, FL, USA
  • Volume
    27
  • Issue
    1
  • fYear
    1991
  • fDate
    1/1/1991 12:00:00 AM
  • Firstpage
    374
  • Lastpage
    379
  • Abstract
    A cable design is presented, along with the development of terminal connectors. The characterization tests of a first run sample of high-power cable are described. The cable end connectors described have proven ability to conduct large current pulses. In fact, a safety factor of nearly two has been demonstrated for the intended operational levels for the cables. The cable resistance has been shown to approach the DC resistance value 440 μΩ/m in a 1 ms pulse duration. For shorter times, such as the 100 μs point, the cable resistance is higher, approximately 500 μΩ/m. The cable inductance is on the order of 190 nH/m for low-frequency operation and about 15% lower for short times as short as 50 μs
  • Keywords
    electric connectors; power cables; pulsed power technology; safety; DC resistance; cable inductance; end connectors; high-power cable; pulsed power; safety factor; terminal connectors; Coaxial cables; Conductors; Connectors; Laboratories; Magnetic field measurement; Power cables; Power supplies; Switches; Testing; Voltage;
  • fLanguage
    English
  • Journal_Title
    Magnetics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9464
  • Type

    jour

  • DOI
    10.1109/20.101060
  • Filename