• DocumentCode
    765288
  • Title

    Start/Stop Operation in Ion-Implanted Magnetic Bubble Propagation Tracks

  • Author

    Takeuchi, T. ; Kodama, N. ; Toyooka, T. ; Suzuki, R. ; Sugita, Y.

  • Author_Institution
    Central Research Laboratory, Hitachi Ltd.
  • Volume
    1
  • Issue
    5
  • fYear
    1985
  • Firstpage
    570
  • Lastpage
    571
  • Abstract
    To study start/stop operations in ion-implanted magnetic bubble propagation tracks, H2 was implanted at 35 keV and 1 × 1016/cm2 and at 80 keV and 4.4 × 1016/cm2, and set four stop directions both parallel and normal to the linear propagation track. The characteristics were then measured at 100 kHz. From the DC in-plane magnetic field Hdc dependence of the start/stop operating bias field margin, nonnegative Hdc values resulted in a start/stop bias field margin equal to the continuous operation margin. In most experiments, start/stop bias field margins of 8 percent or more were obtained.
  • Keywords
    Hydrogen; Implants; Laboratories; Magnetic field measurement; Magnetics Society;
  • fLanguage
    English
  • Journal_Title
    Magnetics in Japan, IEEE Translation Journal on
  • Publisher
    ieee
  • ISSN
    0882-4959
  • Type

    jour

  • DOI
    10.1109/TJMJ.1985.4548866
  • Filename
    4548866