• DocumentCode
    766864
  • Title

    The accurate measurement of high attenuation at radio frequencies

  • Author

    Kilby, Graham J. ; Smith, Timothy A J ; Warner, Frank L.

  • Author_Institution
    Nat. Phys. Lab., Malvern, UK
  • Volume
    44
  • Issue
    2
  • fYear
    1995
  • fDate
    4/1/1995 12:00:00 AM
  • Firstpage
    308
  • Lastpage
    311
  • Abstract
    Techniques are described which allow the traceable measurement, at low uncertainty levels, of changes in attenuation value in excess of 140 dB at frequencies from 0.5 MHz to 100 MHz. The coherent nature of the dual channel techniques employed allows the changes in the path length through an attenuator, produced when its setting is changed, to be measured accurately even at high attenuation levels
  • Keywords
    attenuation measurement; attenuators; calibration; 0.5 to 100 MHz; 140 dB; accurate measurement; attenuation levels; attenuator; dual channel techniques; path length; phase sensitive detection; radio frequencies; traceable measurement; uncertainty levels; voltage ratio system; Attenuation measurement; Attenuators; Calibration; Frequency measurement; Laboratories; Length measurement; Microwave measurements; Radio frequency; Radiofrequency amplifiers; Voltage;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/19.377838
  • Filename
    377838