• DocumentCode
    767677
  • Title

    The detection properties of ammonia SAW gas sensors based on L-glutamic acid hydrochloride

  • Author

    Chi-Yen Shen ; Chun-Pu Huang ; Wang-Tsung Huang

  • Author_Institution
    Dept. of Electr. Eng., I-Shou Univ., Ta-Hsu Hsiang, Taiwan
  • Volume
    52
  • Issue
    10
  • fYear
    2005
  • Firstpage
    1877
  • Lastpage
    1880
  • Abstract
    This study has investigated an improved surface acoustic wave (SAW) ammonia gas sensor based on L-glutamic acid hydrochloride. It presents an excellent reversibility, sensitivity, and repeatability to ammonia. The frequency shift versus ammonia concentration above 40/spl deg/C was a monotonic function, and the limit of detection of the sensor at 50/spl deg/C was 80 ppb.
  • Keywords
    ammonia; bioacoustics; gas sensors; patient diagnosis; surface acoustic waves; 50 degC; L-glutamic acid hydrochloride; ammonia SAW gas sensors; ammonia concentration; frequency shift; repeatability; reversibility; sensitivity; surface acoustic wave; Acoustic sensors; Biosensors; Chemical and biological sensors; Chemical sensors; Delay lines; Frequency; Gas detectors; Surface acoustic wave devices; Surface acoustic waves; Temperature sensors;
  • fLanguage
    English
  • Journal_Title
    Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-3010
  • Type

    jour

  • DOI
    10.1109/TUFFC.2005.1561645
  • Filename
    1561645