    MHD-steam thermal power plant electrical stations with zero stack emission

  • Author

    Borghi, C.A. ; Ribani, P.L.

  • Author_Institution
    Istituto di Elettrotech., Bologna Univ., Italy
  • Volume
    11
  • Issue
    1
  • fYear
    1996
  • fDate
    3/1/1996 12:00:00 AM
  • Firstpage
    194
  • Lastpage
    199
  • Abstract
    A system study of a combined cycle MHD-steam thermal power plant electrical station with zero stack emission through recirculation of CO 2, is presented. The design of the MHD generator of the topper is done by means of a quasi-one dimensional optimization model. The technology of the components is conventional. An overall efficiency larger than 40% for power plants with thermal power inputs above 1000 MWth, is obtained
  • Keywords
    air pollution control; carbon compounds; combined cycle power stations; magnetohydrodynamic convertors; magnetohydrodynamic power plants; steam power stations; 1000 MW; CO2; CO2 liquefaction; CO2 recirculation; MHD generator design; combined cycle MHD-steam thermal power plant; overall efficiency; quasi-one dimensional optimization model; topper; zero stack emission; Costs; Design optimization; Firing; Global warming; Life testing; Magnetohydrodynamic power generation; Power generation; Power system modeling; Recycling; Superconducting magnets;