• DocumentCode
    769795
  • Title

    Neutron tomography using small angle scattering data

  • Author

    Treimer, W. ; Strobl, M. ; Hilger, A. ; Peschke, H.J.

  • Author_Institution
    Univ. of Appl. Sci., Berlin, Germany
  • Volume
    52
  • Issue
    1
  • fYear
    2005
  • Firstpage
    386
  • Lastpage
    388
  • Abstract
    Neutron tomographies were performed in a double crystal diffractometer (DCD) of bent crystal type. The recorded data from this DCD include much more information about the object than in common absorption tomography. This is due to the additional simultaneous registration of absorption, refraction, and small angle scattering of the neutron beam. The information especially of the small angle scattering data was used to reconstruct the two-dimensional image of the sample from its projections and to compare to the results of common absorption data images. For the first time, it was possible to reconstruct images of samples using USANS data only. This new imaging signal offers a number of new possibilities in high resolution non destructive testing.
  • Keywords
    diffractometers; image reconstruction; neutron absorption; neutron diffraction; nondestructive testing; tomography; USANS data; absorption tomography; bent crystal type; double crystal diffractometer; high resolution nondestructive testing; image reconstruction; imaging signal; neutron tomography; refraction; small angle scattering; two-dimensional image; Absorption; Diffraction; High-resolution imaging; Image reconstruction; Image resolution; Neutrons; Particle beams; Scattering; Signal resolution; Tomography; Double crystal diffractometer; neutron tomography; scattering contrast; small angle scattering;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.2005.843640
  • Filename
    1417172