DocumentCode :
770850
Title :
Effective Permeability due to High Temperature Annealing in Amorphous Alloy
Author :
Ohura, H. ; Yanagi, R. ; Matsuda, S.
Author_Institution :
AKAI Electric Co., Ltd., D.M.R. Yokohama Lab.
Volume :
2
Issue :
8
fYear :
1987
Firstpage :
752
Lastpage :
753
Abstract :
The effect of heat treatment conditions on the high-frequency characteristics of amorphous materials was studied. In the range 300 kHz to 1 MHz, permeability reached a peak at a heat treatment time of around 100 min., about 20 percent higher than the permeability peak for short duration heat treatment. Permeability increased at 1 MHz for all heat treatment temperatures, peak time decreasing with increase in heat treatment temperature. It was confirmed that it is possible to have both a composition with Tx and Tc close to each other, and to use water quenching heat treatment.
Keywords :
Amorphous materials; Annealing; Frequency; Heat treatment; Magnetic field measurement; Permeability measurement; Temperature; Thin film devices; Transistors; Water heating;
fLanguage :
English
Journal_Title :
Magnetics in Japan, IEEE Translation Journal on
Publisher :
ieee
ISSN :
0882-4959
Type :
jour
DOI :
10.1109/TJMJ.1987.4549599
Filename :
4549599
Link To Document :
بازگشت