DocumentCode
779196
Title
Some High Voltage Pulse Techniques in Use at Argonne
Author
Lewis, R.N. ; Jung, E.A. ; Chapman, G.L. ; Van Loon, L.S. ; Romanowski, T.A.
Author_Institution
Electronics Division
Volume
13
Issue
2
fYear
1966
fDate
4/1/1966 12:00:00 AM
Firstpage
84
Lastpage
88
Abstract
Instrumentation requirements at Argonne have necessitated the development of circuits capable of delivering megawatt-level pulses into various types of loads. The allowed delay time between the command signal and the output pulse has ranged from a few nanoseconds to a few microseconds and the allowed time jitter has generally been in the low nanosecond region. This report will consider some of the components and circuits and some of the system design concepts in current use at Argonne for high voltage-high current pulse instrumentation.
Keywords
Capacitors; Delay effects; Electrons; Instruments; Jitter; Laboratories; Pulse circuits; Space vector pulse width modulation; Switches; Voltage;