• DocumentCode
    77997
  • Title

    Frequency-Domain Decoupling-Correction Method for Wind Tunnel Strain-Gauge Balance

  • Author

    Shuang-Long Yang ; Ke-Jun Xu

  • Author_Institution
    Sch. of Electr. & Autom. Eng., Hefei Univ. of Technol., Hefei, China
  • Volume
    62
  • Issue
    9
  • fYear
    2013
  • fDate
    Sept. 2013
  • Firstpage
    2596
  • Lastpage
    2608
  • Abstract
    A frequency-domain decoupling-correction (FDC) method based on frequency-domain parameter matrix inversion is proposed to solve the problems of cross-axis dynamic coupling interference and dynamic error existing in the main channel output for multiaxis force sensors, for example, wind tunnel strain-gauge balance. The frequency-domain decoupling-correction function is calculated by means of power spectrum estimation according to the sensor step response experimental data, and the windowing approach is adopted to overcome the calculation error caused by the cycle extension of the intercepting data when FFT or IFFT is conducted. The method of FDC based on high/low-frequency signal decomposition is put forward in the process of the dynamic decoupling correction for the sensor output. The low-frequency components are decoupled and corrected by the method of static linear decoupling and static linear correction, and the high-frequency components are decoupled and corrected by the method of frequency-domain parameter matrix inversion in order to overcome the boundary aliasing error and the Gibbs phenomenon caused by the cycle extension of the intercepting data when FFT or IFFT is conducted. According to the static relationship between the sensor input and output, the static characteristic between the sensor input and the sensor dynamic decoupling-correction result is reconstructed so as to ensure that the sensor static characteristic remains unchanged. The dynamic decoupling-correction method is applied to the bar-shaped strain-gauge balance to validate its effectiveness. The result shows that the cross-axis dynamic coupling error ratios are reduced from 98.09% to less than 2%, and the adjust time of the balance main channel step response is shortened from nearly 4 s to less than 6 ms with the overshoot being reduced from 111.24% to less than 5% at the same time. The proposed method can substantially reduce the cross-axis dynamic coupling interference and further improve - he response speed of the balance.
  • Keywords
    force sensors; strain sensors; wind tunnels; Gibbs phenomenon; cross-axis dynamic coupling interference; dynamic decoupling-correction method; dynamic error; frequency-domain decoupling-correction method; multiaxis force sensors; power spectrum estimation; sensor dynamic; wind tunnel strain-gauge balance; Dynamic coupling interference; dynamic decoupling-correction; dynamic error; frequency domain; multiaxis force sensor; wind tunnel strain-gauge balance;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/TIM.2013.2259100
  • Filename
    6520877