DocumentCode
785284
Title
Electromagnetic analysis of a shielded gap for the RFX conducting shell
Author
Zollino, Giuseppe
Author_Institution
Padova Univ., Italy
Volume
31
Issue
6
fYear
1995
fDate
11/1/1995 12:00:00 AM
Firstpage
3533
Lastpage
3535
Abstract
The numerical analyses carried out to assess the effectiveness of an electromagnetic shield are presented in the paper. The shield should-reduce the field errors on the magnetic configuration due to the gaps of a conducting shell of a nuclear fusion device, already in operation. The shield dimensions are limited by other components, so the actual effectiveness had to be accurately computed. The finite element method was used for 3-D eddy current analysis and the results were compared with measurements on the actual shell. The stray magnetic field in the plasma region with the shielded gap was 30% lower than with the unshielded gap
Keywords
electromagnetic fields; electromagnetic shielding; finite element analysis; fusion reactor design; fusion reactor reaction chamber; fusion reactors; reversed field pinch; 3D eddy current analysis; RFX conducting shell; effectiveness; electromagnetic shield; finite element method; magnetic configuration; nuclear fusion device; numerical analyses; plasma region; shielded gap; stray magnetic field; Eddy currents; Electromagnetic analysis; Electromagnetic shielding; Finite element methods; Fusion reactors; Magnetic devices; Magnetic field measurement; Magnetic shielding; Numerical analysis; Plasma measurements;
fLanguage
English
Journal_Title
Magnetics, IEEE Transactions on
Publisher
ieee
ISSN
0018-9464
Type
jour
DOI
10.1109/20.489560
Filename
489560
Link To Document