• DocumentCode
    787019
  • Title

    A Gamma Compensated Neutron Ionization Chamber Detector for the Nerva Reactor

  • Author

    Todt, William H.

  • Author_Institution
    Westinghouse Electric Corporation Electronic Tube Division Elmira, New York
  • Volume
    15
  • Issue
    1
  • fYear
    1968
  • Firstpage
    9
  • Lastpage
    14
  • Abstract
    A compensated ionization chamber, the WX-5362, has been developed for use in the NERVA program as a neutron flux detector for reactor control. The chamber has been designed to withstand the extremes of radiation, temperature, shock and vibration associated with the NERVA reactor.
  • Keywords
    Current density; Electric shock; Gamma ray detection; Gamma ray detectors; Inductors; Ionization chambers; Neutrons; Temperature; Testing; Vibrations;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1968.4324823
  • Filename
    4324823