DocumentCode :
789865
Title :
Calibration of the Self-Powered Neutron Flux Monitor in a Simulated PWR Lattice
Author :
Baldwin, M.N. ; Rogers, J.E.
Author_Institution :
The Babcock & Wilcox Company Lynchburg, Virginia
Volume :
16
Issue :
1
fYear :
1969
Firstpage :
171
Lastpage :
176
Abstract :
The response of a rhodium all-solid, self-powered incore monitor was measured in a critical assembly mock-up of a typical PWR. The detector signal strength and the power density of adjacent fuel rods were correlated. The detector background, typically 2 to 5%, was highly dependent on the detector environment as well as the incident gamma flux.
Keywords :
Assembly; Boron; Calibration; Detectors; Inductors; Lattices; Monitoring; Neutrons; Signal detection; Wires;
fLanguage :
English