  • Abstract
    Fatigue of low-tin lead-base solder was studied at different strain rates. The effect of tensile hold time (low strain rate) in reducing the number of cycles to failure was found to be much more dramatic than the effect of ramp time (higher strain rate). While increasing up to 1 h time per cycle for no-hold tests did not lead to fatigue life saturation, an increase in tensile hold time over a few minutes led to saturation in the number of cycles to failure. Differences in effects of hold and ramp were attributed to different mechanisms of solder fatigue fracture. It is concluded that fatigue life prediction of solder should be based on tests involving hold time
  • Keywords
    failure analysis; fatigue testing; lead alloys; materials testing; soldering; thermal stress cracking; tin alloys; 5 s to 1 h; SnPb solders; effect of ramp time; effect of tensile hold time; fatigue fracture mechanisms; fatigue life; fatigue life prediction; no-hold tests; number of cycles to failure; solder fatigue fracture; strain rate effects; temperature cycling; tests involving hold time; Capacitive sensors; Failure analysis; Fatigue; Lead; Life testing; Soldering; Temperature; Tensile strain; Tensile stress; Thermomechanical processes;
  • fLanguage
    English
  • Journal_Title
    Components, Hybrids, and Manufacturing Technology, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0148-6411
  • Type

    jour

  • DOI
    10.1109/33.49003
  • Filename
    49003