• DocumentCode
    794018
  • Title

    Optimized desoak system for IC panel test handlers

  • Author

    Pfahnl, Andreas C. ; Dunn, John, Jr. ; Muller, Luis A.

  • Author_Institution
    Teradyne Inc, Bedford, MA, USA
  • Volume
    25
  • Issue
    2
  • fYear
    2002
  • fDate
    4/1/2002 12:00:00 AM
  • Firstpage
    120
  • Lastpage
    126
  • Abstract
    This paper presents a unique airflow-based thermal system that returns thermally conditioned integrated circuit (IC) devices to a near ambient temperature level. This "desoak" thermal system addresses specific requirements of new IC panel (lead frame and strip) test handlers, which have very high peak processing capabilities and can operate stand-alone or in-line. Analyses are presented for estimating the heating and cooling loads, and the IC device temperature response. Temperature control methods are described that help minimize the system size. The hardware design is detailed along with experimental data that verifies the cooling capacity of the system.
  • Keywords
    ball grid arrays; cooling; heat sinks; integrated circuit packaging; integrated circuit testing; temperature control; thermal management (packaging); BGA type devices; IC panel test handlers; airflow-based thermal system; cooling capacity; cooling loads; hardware design; heat sink; heating loads; lead frame; optimized desoak system; strip; temperature control methods; temperature response; thermally conditioned IC devices; Boundary conditions; Circuit testing; Cooling; Hardware; Integrated circuit testing; Strips; System testing; Temperature control; Temperature distribution; Thermal resistance;
  • fLanguage
    English
  • Journal_Title
    Electronics Packaging Manufacturing, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1521-334X
  • Type

    jour

  • DOI
    10.1109/TEPM.2002.1021637
  • Filename
    1021637