Abstract
This paper presents the results of in-core experiments conducted to demonstrate the performance of microwave neutron flux detectors. For a microwave resonant cavity, a frequency shift, as caused by a neutron-generated plasma within the cavity, results in a detection technique capable of covering up to six decades of reactor power.
Keywords
Atomic measurements; Coaxial cables; Detectors; Inductors; Microwave sensors; Neutrons; Plasma measurements; Resonance; Resonant frequency; Thermal sensors;