• DocumentCode
    797966
  • Title

    Liquid Cooling of Power Thyristors

  • Author

    Golden, Forest B.

  • Author_Institution
    Semiconductor Products Department, General Electric Company, Auburn, N.Y. 13021.
  • Issue
    5
  • fYear
    1972
  • Firstpage
    601
  • Lastpage
    606
  • Abstract
    A method of determining a given heat exchanger´s thermal properties from the characteristics of the cooling medium is discussed. A test method is presented with an example which helps to clarify the results. It is concluded from running tests using three to four different liquids that heat exchanger thermal performance data can be derived for liquids having a wide range of liquid properties.
  • Keywords
    Fluid flow; Geometry; Heat sinks; Liquid cooling; Testing; Thermal conductivity; Thermal resistance; Thyristors; Turning; Water heating;
  • fLanguage
    English
  • Journal_Title
    Industry Applications, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0093-9994
  • Type

    jour

  • DOI
    10.1109/TIA.1972.349789
  • Filename