DocumentCode :
798031
Title :
Automatic-Ranging Picoammeter for Reactor Control and Protection
Author :
Ball, R.M. ; Lovallo, J.M.
Author_Institution :
The Babcock & Wilcox Company Nuclear Development Center Lynchburg, Virginia
Volume :
18
Issue :
1
fYear :
1971
Firstpage :
435
Lastpage :
437
Abstract :
An automatic-ranging picoammeter covering full-scale ranges from 3 X 10-11 to 1 X 10-3amperes with a 50% over-range capability has been designed, built, tested, and installed for use with Babcock & Wilcox´s Lynchburg Pool Reactor. The unit incorporates three major improvements over previous instrumentation and commercially available equipment: (1) elimination of manual range changing, (2) provision for adjustable power level trips throughout the operating range of the reactor, and (3) provision for a trip function upon detection of a period shorter than that preset into the instrument.
Keywords :
Automatic control; Automatic testing; Differential amplifiers; Inductors; Instruments; Operational amplifiers; Protection; Reactor instrumentation; Safety; Switches;