DocumentCode
798715
Title
Performance of the ANL Dynamitron Tandem
Author
Cox, S.A. ; Hanley, P.R.
Author_Institution
Argonne National Laboratory, Argonne, Illinois
Volume
18
Issue
3
fYear
1971
fDate
6/1/1971 12:00:00 AM
Firstpage
108
Lastpage
112
Abstract
The Dynamitron Tandem Accelerator is now fully operational at ANL. Measurements of beam performance are reported. The dc proton beam current obtained at 8.0 MeV was 53 ¿A. Peak pulsed proton and deuteron currents measured with a fast Faraday cup were 110.0 ¿A at 1.3 nsec FWHM and 700 ¿A at 2.0 nsec FWHM, respectively. Beam energy stability (¿E at E) was less than 140 eV at 1.88 MeV and 820 eV at 6.00 MeV as indicated by the thin target yield of 7Li (p,n)7Be and 27A1 (p,n)27Si. Operational experience has shown that the system is highly reliable. The tandem has logged 1800 high voltage operational hours without any service to components within the pressure vessel, since the last opening of the machine over nine months ago.
Keywords
Inductors; Laboratories; Magnetic separation; Magnetic switching; Neutrons; Particle beams; Physics; Proton accelerators; Pulse measurements; Voltage;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.1971.4325975