• DocumentCode
    798715
  • Title

    Performance of the ANL Dynamitron Tandem

  • Author

    Cox, S.A. ; Hanley, P.R.

  • Author_Institution
    Argonne National Laboratory, Argonne, Illinois
  • Volume
    18
  • Issue
    3
  • fYear
    1971
  • fDate
    6/1/1971 12:00:00 AM
  • Firstpage
    108
  • Lastpage
    112
  • Abstract
    The Dynamitron Tandem Accelerator is now fully operational at ANL. Measurements of beam performance are reported. The dc proton beam current obtained at 8.0 MeV was 53 ¿A. Peak pulsed proton and deuteron currents measured with a fast Faraday cup were 110.0 ¿A at 1.3 nsec FWHM and 700 ¿A at 2.0 nsec FWHM, respectively. Beam energy stability (¿E at E) was less than 140 eV at 1.88 MeV and 820 eV at 6.00 MeV as indicated by the thin target yield of 7Li (p,n)7Be and 27A1 (p,n)27Si. Operational experience has shown that the system is highly reliable. The tandem has logged 1800 high voltage operational hours without any service to components within the pressure vessel, since the last opening of the machine over nine months ago.
  • Keywords
    Inductors; Laboratories; Magnetic separation; Magnetic switching; Neutrons; Particle beams; Physics; Proton accelerators; Pulse measurements; Voltage;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1971.4325975
  • Filename
    4325975