• DocumentCode
    804134
  • Title

    Geometrical similarities of the Orlov and Tuy sampling criteria and a numerical algorithm for assessing sampling completeness

  • Author

    Metzler, S.D. ; Bowsher, J.E. ; Jaszczak, R.J.

  • Author_Institution
    Dept. of Radiol., Duke Univ. Med. Center, Durham, NC, USA
  • Volume
    50
  • Issue
    5
  • fYear
    2003
  • Firstpage
    1550
  • Lastpage
    1555
  • Abstract
    Tuy and others have derived a sufficiency condition for complete sampling using a cone-beam geometry. Herein, we express Tuy´s cone-beam condition in the language and geometry of Orlov´s condition for parallel-beam collimation. One may determine from this condition what volume is completely sampled. This inversion has been implemented in software. The software determines a lower bound on the completely sampled volume for arbitrary orbits.
  • Keywords
    computerised tomography; Orlov´s condition; Tuy´s condition; cone-beam; parallel-beam collimation; Apertures; Biomedical engineering; Biomedical imaging; Collimators; Electron microscopy; Geometry; Image reconstruction; Orbits; Radiology; Sampling methods;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.2003.817385
  • Filename
    1236965