• DocumentCode
    80623
  • Title

    Manikin-Integrated Digital Measuring System for Assessment of Infant Cardiopulmonary Resuscitation Techniques

  • Author

    Jiheum Park ; Chiyul Yoon ; Jung Chan Lee ; Jae Yun Jung ; Do Kyun Kim ; Young Ho Kwak ; Hee Chan Kim

  • Author_Institution
    Interdiscipl. Program of Bio-Eng., Seoul Nat. Univ., Seoul, South Korea
  • Volume
    18
  • Issue
    5
  • fYear
    2014
  • fDate
    Sept. 2014
  • Firstpage
    1659
  • Lastpage
    1667
  • Abstract
    The process of cardiopulmonary resuscitation (CPR) involves various components that must be followed to deliver high quality of CPR. While the components commonly apply to CPR for all ages from infant to adult, there are several different suggestions for infant CPR such as two-thumb CPR and two-finger CPR. However, the comprehensive evaluation based on all these components has been difficult in the absence of proper evaluation tool. Here, we developed a new manikin-integrated, digital measuring system that objectively estimates overall performance of infant CPR by evaluating individual CPR components one by one including different hand placements. The system collects and analyzes data to present estimations in digital scores according to a new evaluation index constructed based on the previously verified one. The feasibility of the system was validated through simulations with beginners and experts in first aid, resulting in statistically significant differences between the two groups with the indication of specific weaknesses for each group which may provide a basis for creating customized CPR training strategy in compliance with the personal level. We believe that the system would become a valuable assessment tool not only for infant CPR but also for the CPR technique, in general, by reflecting every component in the evaluation.
  • Keywords
    biomedical measurement; first aid; paediatrics; assessment; evaluation index; hand placements; infant cardiopulmonary resuscitation techniques; manikin-integrated digital measuring system; proper evaluation tool; two-finger CPR; two-thumb CPR; Biomedical measurement; Fingers; Force; Guidelines; Indexes; Pediatrics; Ventilation; Basic life support (BLS); infant cardiopulmonary resuscitation (CPR); performance evaluation; scoring system;
  • fLanguage
    English
  • Journal_Title
    Biomedical and Health Informatics, IEEE Journal of
  • Publisher
    ieee
  • ISSN
    2168-2194
  • Type

    jour

  • DOI
    10.1109/JBHI.2013.2288641
  • Filename
    6655886