DocumentCode :
808167
Title :
A Multiwire Proportional Counter with Integral Readout Delay Line
Author :
Emming, J.G. ; Gilland, J.R.
Author_Institution :
Ball Brothers Research Corporation Boulder, Colorado 80302
Volume :
20
Issue :
1
fYear :
1973
Firstpage :
145
Lastpage :
154
Abstract :
A new concept for delay line readout of multiwire proportional counters for detecting the position of ionizing particles is described. It significantly reduces the complexity and cost of a multiwire system compared to alternative methods, making it attractive for space flight applications. This integral delay chamber can provide spatial resolution approaching 0.1 mm using Fe55, provided careful consideration is given to geometrical parameters that determine delay line bandwidth and phase distortion. For a chamber of 35 by 35 cm2 a delay of 20 ns/cm and attenuation of 0.05 dB/cm has been obtained. The delay line characteristics and electronic resolution, using a peak detection method, are given as a function of chamber geometry.
Keywords :
Anodes; Cathodes; Coils; Costs; Counting circuits; Delay lines; Electrons; Geometry; Spatial resolution; Wires;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1973.4326899
Filename :
4326899
Link To Document :
بازگشت