• DocumentCode
    808285
  • Title

    Proton Meter for NAL External Beam Lines

  • Author

    Kerns, Cordon R.

  • Author_Institution
    National Accelerator Laboratory Batavia, Illinois
  • Volume
    20
  • Issue
    1
  • fYear
    1973
  • Firstpage
    204
  • Lastpage
    208
  • Abstract
    Accurate beam intensity and total charge per accelerator pulse are important data for a number of experiments performed at NAL. The beam-current transformer and its electronics are operable in a beam intensity of 1010 protons, or more, delivered within a time interval of 100 ¿s. Special features of the design include both analog and digital outputs. The beam toroid is completely external to the vacuum pipe, giving optimum vacuum conditions. In situ test-signal injection and toroidalcore degaussing are incorporated.
  • Keywords
    Computer displays; Electromagnetic shielding; Magnetic cores; Monitoring; Noise cancellation; Noise level; Particle beams; Proton accelerators; Structural beams; Transformer cores;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1973.4326908
  • Filename
    4326908