• DocumentCode
    808943
  • Title

    Partial-discharge-inception testing on low-voltage motors

  • Author

    Bogh, Dennis ; Coffee, Jeff ; Stone, Greg ; Custodio, Jim

  • Author_Institution
    Gen. Electr.-Motors, Woodinville, WA, USA
  • Volume
    42
  • Issue
    1
  • fYear
    2006
  • Firstpage
    148
  • Lastpage
    154
  • Abstract
    This is a review of one manufacturer´s efforts toward testing National Electrical Manufacturers Association (NEMA) low-voltage motor insulation for compatibility with adjustable-speed drives (ASDs). Partial-discharge-inception-voltage (PDIV) measurements were selected as a tool to evaluate the future performance of the stator insulation system to resist deterioration by the drives. PDIV measurement is explained in terms of procedure and accuracy. Data are presented from tests made on motors from several prominent manufacturers.
  • Keywords
    insulation testing; machine insulation; machine testing; motor drives; partial discharges; stators; variable speed drives; voltage measurement; National Electrical Manufacturers Association; adjustable speed drives; deterioration resistance; low-voltage motors insulation; partial discharge inception testing; stator insulation system; AC motors; Chemical industry; Dielectrics and electrical insulation; IEC standards; Insulation testing; Manufacturing; Partial discharges; Pulse width modulation; Variable speed drives; Voltage; MG1 Part 31; motor insulation; partial-discharge-inception voltage (PDIV);
  • fLanguage
    English
  • Journal_Title
    Industry Applications, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0093-9994
  • Type

    jour

  • DOI
    10.1109/TIA.2005.861369
  • Filename
    1583843