Title :
Accurate measurement of total attenuation coefficient of thin tissue with optical coherence tomography
Author :
Kholodnykh, Alexander I. ; Petrova, Irina Y. ; Motamedi, Massoud ; Esenaliev, Rinat O.
Author_Institution :
Center for Biomed. Eng., Univ. of Texas Med. Branch, Galveston, TX, USA
Abstract :
Noninvasive accurate measurements of tissue optical properties are needed for many diagnostic and therapeutic applications. Optical coherence tomography (OCT) recently proposed for high-resolution imaging in tissue can potentially be applied for accurate, noninvasive, and high-resolution measurement of tissue total attenuation coefficient. However, confocal function (dependence of OCT sensitivity on the distance of probed site from the focal plane of the objective lens) and multiple scattering substantially limit the accuracy of the measurement with the OCT technique. We studied the influence of the confocal function and multiple scattering on the accuracy of the measurement and proposed methods that provide measurement of the total attenuation coefficient with a significantly reduced systematic error. Experiments were performed in tissue phantoms and porcine and human skin in vitro and in vivo. Our data indicate that the tissue total attenuation coefficient can noninvasively be measured in vivo with the accuracy of 5%-10% in the range from 0.5 to 17 mm-1 and about 20% in the range up to 40 mm-1. These results suggest that the proper correction of the OCT-based measurement for the confocal function and multiple scattering provides absolute values of tissue total attenuation coefficient with high accuracy and resolution that may not be achievable by other optical techniques in vivo.
Keywords :
absorption coefficients; bio-optics; biological tissues; biomedical optical imaging; image resolution; light scattering; measurement errors; optical focusing; optical tomography; phantoms; skin; OCT sensitivity; confocal function; diagnostic applications; focal plane; high-resolution imaging; human skin; in vitro; in vivo; multiple scattering; noninvasive accurate measurements; objective lens; optical coherence tomography; porcine skin; probed site; systematic error; therapeutic applications; thin tissue; tissue optical properties; tissue phantoms; total attenuation coefficient accurate measurement; Attenuation measurement; High-resolution imaging; Humans; Imaging phantoms; In vivo; Lenses; Optical attenuators; Optical scattering; Optical sensors; Tomography;
Journal_Title :
Selected Topics in Quantum Electronics, IEEE Journal of
DOI :
10.1109/JSTQE.2003.814194