DocumentCode :
814941
Title :
Differential Current Pulse Preamplifier for Fission Counters
Author :
De Lorenzo, J.T. ; Clay, W.T. ; Guerrant, G.C.
Author_Institution :
Oak Ridge National Laboratory Oak Ridge, Tennessee 37830
Volume :
21
Issue :
1
fYear :
1974
Firstpage :
757
Lastpage :
762
Abstract :
A current-pulse preamplifier with a differential input was developed for use with fission counters where there might be severe electrical interference. Tests with a vacuum tester coil show only a slight alteration of the normal noise background curve by the differential preamplifier but a great alteration by a single-ended preamplifier. Additionally, measurements show that if a differential current signal is obtained from the fission counter, the differential preamplifier can improve the signal-to-noise ratio (for electronic noise) nearly a factor of ¿2 over that of a single-ended unit. Tests of five prototypes built by a commercial manufacturer to RDT standards show good uniformity of performance, including gain stability, rise time, and linearity, well within the specified requirements.
Keywords :
Background noise; Coils; Counting circuits; Current measurement; Interference; Noise measurement; Preamplifiers; Prototypes; Signal to noise ratio; Testing;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1974.4327545
Filename :
4327545
Link To Document :
بازگشت