• DocumentCode
    816339
  • Title

    Electronics for Drift Chambers

  • Author

    Verweij, H.

  • Author_Institution
    CERN, Geneva, Switzerland
  • Volume
    22
  • Issue
    1
  • fYear
    1975
  • Firstpage
    437
  • Lastpage
    440
  • Abstract
    Signals from sense wires in drift chambers are of ¿A amplitude and nsec duration. Their time position depends on the drift time and indicates at what distance from the wire the particles passed through the chamber. These times must be measured with accuracies of the order of 2 nsec. A review of circuits and techniques to detect the signals and to measure drift times is given.
  • Keywords
    Circuits; Electron mobility; Position sensitive particle detectors; Pulse amplifiers; Signal detection; Signal resolution; Spatial resolution; Time measurement; Wideband; Wire;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1975.4327676
  • Filename
    4327676