• DocumentCode
    82207
  • Title

    Wound Rotor to Induction Motor and VFD Conversion Case Study

  • Author

    Kozlowski, M.

  • Author_Institution
    ABB Process Autom. Pulp & Paper, Greenville, SC, USA
  • Volume
    49
  • Issue
    3
  • fYear
    2013
  • fDate
    May-June 2013
  • Firstpage
    1221
  • Lastpage
    1227
  • Abstract
    This paper will present a method, which has been used to retrofit vintage wound rotor motors in various applications in the forest products industry. This calculation method was developed due to the end user´s need to retrofit an existing application and the lack of detailed motor data. Specifically, the author will present a case study from an actual project, which was commissioned two years ago. The author will present general background of the application, obstacles to overcome in the retrofit process, calculations, motor application recommendations, and postretrofit site data.
  • Keywords
    induction motor drives; maintenance engineering; rotors; variable speed drives; VFD conversion; forest products industry; induction motor; variable frequency drive; vintage wound rotor motor retrofiting; Cranes; Electric breakdown; Induction motors; Resistors; Rotors; Shafts; Torque; Induction motor; retrofit; variable-frequency drive (VFD); wound-rotor (WR) motor;
  • fLanguage
    English
  • Journal_Title
    Industry Applications, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0093-9994
  • Type

    jour

  • DOI
    10.1109/TIA.2013.2251594
  • Filename
    6475178