    Radiation Induced Common Mode and Individual Wire Current Response of Shielded Twisted Pair Cables

  • Author

    Chivington, E.Paul ; Shaw, Lloyd E. ; Alston, Titus E.

  • Author_Institution
    TRW Defense and Space Systems Redondo Beach, California 90278
  • Volume
    23
  • Issue
    6
  • fYear
    1976
  • Firstpage
    1952
  • Lastpage
    1957
  • Abstract
    An analytical technique and experimental verification are presented for the response of shielded twisted pair cables to ionizing radiation. The common mode current of three sizes of cables is found to vary from 3.6 to 3.9×10-6 Amps/m/cal/cm2-sec. The individual wire current was found to vary from 0.23 to 2.3×10-6 Amps/m/ cal/cm2-sec, over the range of loads considered. The effects of air and multiple exposures are discussed. The model developed is applied to several differential mode configurations.