DocumentCode
825448
Title
Radiation Induced Common Mode and Individual Wire Current Response of Shielded Twisted Pair Cables
Author
Chivington, E.Paul ; Shaw, Lloyd E. ; Alston, Titus E.
Author_Institution
TRW Defense and Space Systems Redondo Beach, California 90278
Volume
23
Issue
6
fYear
1976
Firstpage
1952
Lastpage
1957
Abstract
An analytical technique and experimental verification are presented for the response of shielded twisted pair cables to ionizing radiation. The common mode current of three sizes of cables is found to vary from 3.6 to 3.9Ã10-6 Amps/m/cal/cm2-sec. The individual wire current was found to vary from 0.23 to 2.3Ã10-6 Amps/m/ cal/cm2-sec, over the range of loads considered. The effects of air and multiple exposures are discussed. The model developed is applied to several differential mode configurations.
Keywords
Cable shielding; Circuit testing; Coaxial cables; Electromagnetic measurements; Electron emission; Instruments; Ionizing radiation; Lighting; Performance evaluation; Wire;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.1976.4328605
Filename
4328605
Link To Document