• DocumentCode
    828092
  • Title

    Recent Progress in KEK Preinjector

  • Author

    Fukumoto, S. ; Ishimaru, H. ; Ito, K. ; Kubota, C. ; Sakaue, T. ; Takagi, A. ; Takano, S.

  • Author_Institution
    National Laboratory for High Energy Physics Oho-machi, Tsukuba-gun, Ibaraki, 300-32, Japan
  • Volume
    24
  • Issue
    3
  • fYear
    1977
  • fDate
    6/1/1977 12:00:00 AM
  • Firstpage
    1121
  • Lastpage
    1123
  • Abstract
    The overall accelerating gap length is shortened to 18 cm in the high gradient accelerating column. A sparking rate of less than one per day is achieved by keeping a pressure of 2.5 ?? 10-4 Torr in the column. The column current increases with the column pressure. It is plausible that the increased current is mainly due to molecular ions produced in a plasma expansion cup. The beam, which passes through focusing magnets, is scarcely affected by increasing the column pressure. An ion emissive plasma surface is located by a Langmuir probe. A multiple-canal duoplasmatron with seven anode holes is being developed.
  • Keywords
    Acceleration; Anodes; Hydrogen; Linear particle accelerator; Magnets; Molecular beam applications; Molecular beams; Particle beams; Plasma accelerators; Resistors;