Title :
System for Calibration of Spear Transport Line Toroids
Author :
Huang, T.V. ; Smith, H. ; Crook, K.
Author_Institution :
Stanford Linear Accelerator Center Stanford University, Stanford, California 94305
fDate :
6/1/1977 12:00:00 AM
Abstract :
A one nanosecond pulse generator has been developed for calibration of the intensity monitors (toroids) in the SPEAR transport lines. The generator, located at the toroid, is simple, low cost and resistant to radiation. This paper describes the generator, and its connection to the standard SLAC toroid calibration system.
Keywords :
Calibration; Capacitance; Coaxial cables; Power cables; Pulse amplifiers; Pulse generation; Relays; Space vector pulse width modulation; Voltage; Wiring;
Journal_Title :
Nuclear Science, IEEE Transactions on
DOI :
10.1109/TNS.1977.4329073