• DocumentCode
    830377
  • Title

    Long Radiation Detector System for Beam Loss Monitoring

  • Author

    Balsamo, J. ; Fewell, N.M. ; Klein, J.D. ; Witkover, R.L.

  • Author_Institution
    Brookhaven National Laboratory Upton, New York 11973
  • Volume
    24
  • Issue
    3
  • fYear
    1977
  • fDate
    6/1/1977 12:00:00 AM
  • Firstpage
    1807
  • Lastpage
    1809
  • Abstract
    This paper describes the Long Radiation Monitor (LRM) system installed at the 200 MeV linac at Brookhaven National Laboratory. This system allows observation of both the spatial and temporal character of the losses in the linac and its transport lines. An array of large diameter gas filled coaxial cables are used as extended ion chambers to detect the losses. The output signals are available as a histogram, video waveforms, and numerical data via the computer. A fast beam interrupt is also provided. The detector characteristics and details of the processing electronics are presented. Results of studies of longitudinal, steering and focusing losses are described.
  • Keywords
    Coaxial cables; Electrons; Histograms; Isotopes; Laboratories; Linear particle accelerator; Protons; Pulse measurements; Radiation detectors; Radiation monitoring;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1977.4329094
  • Filename