    Internal SGEMP Response of a Communications Van to AURORA Irradiation

  • Author

    Meyer, Owen L. ; Chadsey, William L. ; Pine, Vernon W.

  • Author_Institution
    Harry Diamond Laboratories, Dept of the Army, 2800 Powder Mill Rd., Adelphi, MD 20783
  • Volume
    24
  • Issue
    6
  • fYear
    1977
  • Firstpage
    2473
  • Lastpage
    2475
  • Abstract
    Results are presented for an internal system-generated electromagnetic pulse (SGEMP) experiment conducted at the AURORA facility on a communications system in its shelter, noting effects of various experimental conditions. Typical fields of 3.28 kV/m and 0.47 Gauss and induced cable currents of 0.42 A compare with computer predictions of 3.5 kV/ m, 1.0 Gauss, and 0.42 A.
  • Keywords
    Communication cables; EMP radiation effects; Gaussian processes; Maxwell equations; Monitoring; Noise reduction; Receiving antennas; System testing; Transmitters; Transmitting antennas;