• DocumentCode
    831889
  • Title

    Stmple Compton Current Density Measurement Technique

  • Author

    Longmire, L. ; Merkel, G. ; Spohn, D.J.

  • Volume
    24
  • Issue
    6
  • fYear
    1977
  • Firstpage
    2484
  • Lastpage
    2486
  • Abstract
    A method is discussed for making highly directional measurements of Compton current density in a radiation environment without the necessity for collimation of source current. The theoretical basis for the sensor is presented and practical design considerations are noted. In addition, experimental results obtained employing the AURORA Flash X-ray Facility as a radiation source and measuring the resulting Compton current density in air over a range of the order of 10´s to 100´s A/m2 using a prototype model of the described sensor are presented.
  • Keywords
    Area measurement; Collimators; Conductors; Current density; Current measurement; Density measurement; Magnetic sensors; Measurement techniques; Prototypes; Sensor phenomena and characterization;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1977.4329241
  • Filename