DocumentCode :
837817
Title :
Stability Measurements at the Vicksi-RF-Systems
Author :
Pelzer, W.
Author_Institution :
Hahn-Meitner-Institut fÿr Kernforschung Berlin GmbH Bereich Kern- und Strahlenphysik Berlin, Germany
Volume :
26
Issue :
2
fYear :
1979
fDate :
4/1/1979 12:00:00 AM
Firstpage :
2202
Lastpage :
2204
Abstract :
Methods and results of stability measurements at the VICKSI-RF-systems are given. Both amplitude- and phase-stability have been measured in the frequency range from 10 to 20 MHz. The short term stability of the amplitude is found to be better than 10-3 and the long term stability is measured to be less than 2 · 10-4. The phase stability has been determined to be better than 0.04 degrees over a period of 20 hours.
Keywords :
Amplitude modulation; Delay; Frequency measurement; Low-frequency noise; Phase detection; Phase measurement; Phase modulation; Signal generators; Stability; Time measurement;