• DocumentCode
    839743
  • Title

    Microprocessor Based Beam Loss Monitor System for the AGS

  • Author

    Witkover, R.L.

  • Author_Institution
    Brookhaven National Laboratory, Upton, New York 11973
  • Volume
    26
  • Issue
    3
  • fYear
    1979
  • fDate
    6/1/1979 12:00:00 AM
  • Firstpage
    3313
  • Lastpage
    3315
  • Abstract
    An array of 120 long radiation monitors (LRM) have been installed around the AGS. Each monitor is an extended coaxial ion chamber, 5 meters long, made from hollow core coaxial transmission cable pressured with argon. The LRM´s are each connected to a low current preamplifier and voltage-to-frequency converter (VFC). The digital output of each channel is fed to a 16 bit counter chip which bridges the bus of an 8085 microprocessor. This circuit is connected to the AGS PDP-10 for data taking or may function as a stand-alone unit. Various operating modes can be selected for data readout. System design and operating performance are described.
  • Keywords
    Circuits; Coaxial cables; Electronic equipment testing; Linear particle accelerator; Microprocessors; Monitoring; Radiation detectors; Signal to noise ratio; Structural beams; Voltage;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1979.4330020
  • Filename
    4330020