• DocumentCode
    839902
  • Title

    Impulse Breakdown of Positive and Negative Rod-Plane Gaps in SF6-N2 Mixtures

  • Author

    Kuffel, E. ; Yializis, A.

  • Author_Institution
    University of Windsor Electrical Engineering Department
  • Issue
    6
  • fYear
    1978
  • Firstpage
    2359
  • Lastpage
    2366
  • Abstract
    The paper presents experimental data on negative and positive breakdown characteristics of rod-plane gaps in SF6, N2 and SF6-N2 mixtures. The gap lengths studied extended from 5 to 50mms over a pressure range from 300 Torr to 5 bar.
  • Keywords
    Breakdown voltage; Cable insulation; Cables; Dielectrics and electrical insulation; Electric breakdown; Electrodes; Gas insulation; Nitrogen; Pressure measurement; Sulfur hexafluoride;
  • fLanguage
    English
  • Journal_Title
    Power Apparatus and Systems, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9510
  • Type

    jour

  • DOI
    10.1109/TPAS.1978.354742
  • Filename
    4181691