DocumentCode :
840202
Title :
Subnanosecond Chopper-Buncher System for Heavy Ions
Author :
Ben-Zvi, I. ; Bernstein, D. ; Birk, M. ; Feldman, H. ; Gal, Y. ; Sokolowski, J.S.
Author_Institution :
Department of Nuclear Physics, The Weizmann Institute of Science, Rehovot, Israel
Volume :
26
Issue :
3
fYear :
1979
fDate :
6/1/1979 12:00:00 AM
Firstpage :
3436
Lastpage :
3438
Abstract :
A chopper-buncher for a 14UD Pelletron is being assembled and tested. The system was designed to produce heavy ion bursts of approximately 100 ps at 15% transmission. This system will be used for nuclear physics fast timing experiments and can also serve as an injector to a linac. The ion source beam is sliced by a deflector-redeflector chopper operating at 1.68 MHz. The chopper is followed by a 3rd harmonic corrected buncher, which produces bunches of less than 1 ns duration at the target area, for ions up to mass 60. Further bunching, down to 100 ps, is accomplished by a superconducting cavity operating at 430 MHz.
Keywords :
Choppers; Electrostatics; Ion accelerators; Ion sources; Lenses; Linear particle accelerator; Magnetic separation; Nuclear physics; Superconducting magnets; Timing;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1979.4330061
Filename :
4330061
Link To Document :
بازگشت