    Traditional Time - Current Curves Are Not Enough, Adding I^{2}{t} Considerations

  • Author

    Papallo, Thomas ; Valdes, Marcelo E.

  • Author_Institution
    GE Energy Ind. Solutions, Plainville, CT, USA
  • Volume
    49
  • Issue
    1
  • fYear
    2013
  • fDate
    Jan.-Feb. 2013
  • Firstpage
    264
  • Lastpage
    274
  • Abstract
    Overcurrent device selectivity has always been desirable in power distribution systems. Recent changes in the U.S. National Electrical Code (NFPA 70-2005 and subsequent) have increased the demand for near perfect selectivity. Simultaneously, heightened sensitivity to the effect of slow clearing times on arc flash hazard has increased the need for fast and sensitive overcurrent protection, particularly at the larger upper tier overcurrent devices. When the selectivity solution is to oversize or to slow down protection at midlevel feeders above the branch circuit breakers (CBs), arc-flash-incident energy at higher levels in systems can reach unacceptable levels. Optimized protection and selectivity may be achieved by optimizing instantaneous settings and algorithms in upstream protectors. Such selectivity may be accomplished primarily by understanding the current-limiting behavior of the downstream protective device and understanding the thermal capacitance needed to melt upstream fuse elements or intentional damping added to upstream CB trip units. When CBs trip in subcycle times and clearing times are instantaneous, traditional time-current curves (TCCs) are insufficient to correctly demonstrate device operation. The authors will describe two graphical representations based on the I2t let-through of the downstream device and I2t requirement to trip the upstream device. The I2t representations more effectively describe protective device behavior in the instantaneous region below 0.010 s normally excluded in traditional TCCs. Furthermore, a technique, a theoretical basis, and a proposed test protocol that are suitable for a wide range of devices will be presented.
  • Keywords
    arcs (electric); circuit breakers; current limiters; overcurrent protection; power distribution; I2t considerations; NFPA 70-2005; U.S. National Electrical Code; arc flash hazard; arc-flash-incident energy; branch circuit breakers; current-limiting behavior; downstream protective device; graphical representations; intentional damping; melt upstream fuse elements; midlevel feeders; overcurrent device selectivity; overcurrent protection; power distribution systems; thermal capacitance; traditional time-current curves; upstream protectors; Arc discharges; Circuit breakers; Circuit faults; Fault currents; Fuses; Limiting; Visualization; Arc flash protection; current-limiting circuit breakers (CBs); current-limiting fuses; selectivity;
  • fLanguage
    English
  • Journal_Title
    Industry Applications, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0093-9994
  • Type

    jour

  • DOI
    10.1109/TIA.2012.2231659
  • Filename
    6374245