DocumentCode
845583
Title
Low THD bandpass-based oscillator using multilevel hard limiter
Author
Bahmani, F. ; Sánchez-Sinencio, E.
Author_Institution
Dept. of Electr. Eng., Texas A&M Univ., College Station, TX
Volume
1
Issue
2
fYear
2007
fDate
4/1/2007 12:00:00 AM
Firstpage
151
Lastpage
160
Abstract
In order to reduce the total harmonic distortion (THD) of a bandpass-based oscillator, instead of using a conventional hard limiter, a multilevel hard limiter (MHL) is proposed which inherently removes the third and the fifth-order harmonics from the frequency spectrum of its output signal. The input-output characteristic of the proposed MHL contains slope values of only zero and infinity, making it easy to implement. The optimal height and width of each stair of the MHL characteristic are derived. Measurement results show that for the same bandpass filter, the proposed approach shows 14 dB improvement in the THD of the output signal with respect to the conventional two-level hard limiter (comparator). The oscillator has been fabricated in TSMC 0.35 mum CMOS process and the die occupies an area of about 3.15 mm2 . The oscillator chip prototype operates at the frequency of 10.7 MHz, consumes 40 mA current from a 3.3 V power supply and yields a THD of -53 dB
Keywords
CMOS integrated circuits; MMIC oscillators; band-pass filters; comparators (circuits); harmonic distortion; limiters; 0.35 micron; 10.7 MHz; 3.3 V; 40 mA; CMOS process; bandpass filter; bandpass-based oscillator; comparator; frequency spectrum; harmonics; multilevel hard limiter; total harmonic distortion;
fLanguage
English
Journal_Title
Circuits, Devices & Systems, IET
Publisher
iet
ISSN
1751-858X
Type
jour
DOI
10.1049/iet-cds:20060072
Filename
4197892
Link To Document