Title
Transient stability of superconducting alternators
Author
Furuyama, Sayuki ; Kirtley, J.L., Jr.
Author_Institution
Massachusetts Institute of Technology, Cambridge, Massachusetts
Volume
94
Issue
2
fYear
1975
fDate
3/1/1975 12:00:00 AM
Firstpage
320
Lastpage
328
Abstract
A simulation study is performed for the purpose of determining the transient stability characteristics of superconducting alternators. This simulation is compared with an equal area criterion method. It is found that superconducting machines have good transient stability characteristics, that field forcing is not particularly helpful nor necessary. It is also found that the equal area criterion is useful for computing critical clearing times, if voltage behind subtransient reactance is held constant.
Keywords
Alternators; Damping; Electromagnetic shielding; Magnetic shielding; Modeling; Power system simulation; Power system stability; Power system transients; Shock absorbers; Voltage;
fLanguage
English
Journal_Title
Power Apparatus and Systems, IEEE Transactions on
Publisher
ieee
ISSN
0018-9510
Type
jour
DOI
10.1109/T-PAS.1975.31857