DocumentCode :
847909
Title :
Performance of the Lead/Liquid Argon Shower Counter System of the Mark II Detector at SPEAR
Author :
Abrams, G.S. ; Blocker, C.A. ; Briggs, D.D. ; Carither, W.C. ; Dieterle, W.E. ; Eaton, M.W. ; Lankford, A.J. ; Pang, C.Y. ; Vella, E.N. ; Breidenbach, M. ; Dorfan, J.M. ; Hanson, G. ; Hitlin, D.G. ; Jenni, P. ; Luth, V.
Author_Institution :
Lawrence Berkeley Laboratory University of California, Berkeley, California 94720
Volume :
27
Issue :
1
fYear :
1980
Firstpage :
59
Lastpage :
63
Abstract :
Although the cryogenic and electronic problems of a large lead/liquid argon shower system such as in the Mark II require considerable attention to detail during design, construction, and set-up, the performance of a large system equals that of small test systems and agrees well with reasonable expectations. The shower detector system of the Mark II has been mechanically, cryogenically, and electronically very reliable during eighteen months of normal operation at SPEAR. Performance has provided a good compromise among the various demands upon shower detection. The system has enabled physics measurements previously untenable to other e+e- detectors.
Keywords :
Aluminum; Argon; Counting circuits; Iron; Linear accelerators; Magnetic flux; Magnetic separation; Physics; Radiation detectors; Strips;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1980.4330802
Filename :
4330802