• DocumentCode
    849232
  • Title

    Analysis of High-Speed CT Scanners for Non-Medical Applications

  • Author

    Schlosser, P.A. ; De Vuono, A.C. ; Kulacki, F.A. ; Munshi, P.

  • Author_Institution
    Nuclear Engineering Program the Ohio State University Columbus, Ohio 43210
  • Volume
    27
  • Issue
    1
  • fYear
    1980
  • Firstpage
    788
  • Lastpage
    794
  • Abstract
    There are non-medical applications for CT (computerized tomographic) scanner technology which are feasible and potentially important. We have identified several applications related to the general problem of measuring cross-sectional density distributions in two-phase flowing mixtures and have analyzed a general class of CT scanner designs which suit these applications. Specifically, this paper reports the results of an analysis of CT scanners which (1) are appropriate for two-phase fluid density measurements, (2) are based upon stationary detector array scanner designs, (3) incorporate a rotating isotopic fan-beam source, (4) permit continuous scanning of the object, and (5) can achieve 10 millisecond scan times.
  • Keywords
    Application software; Computed tomography; Density measurement; Detectors; Fluid flow measurement; Heat transfer; Image reconstruction; Object detection; Phase measurement; Solids;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1980.4330928
  • Filename
    4330928