DocumentCode
851759
Title
Depth measurement in a germanium strip detector
Author
Wulf, E.A. ; Ampe, J. ; Johnson, W.N. ; Kroeger, R.A. ; Kurfess, J.D. ; Phlips, B.F.
Author_Institution
Naval Res. Lab., Washington, DC, USA
Volume
49
Issue
4
fYear
2002
fDate
8/1/2002 12:00:00 AM
Firstpage
1876
Lastpage
1880
Abstract
We have demonstrated the ability to determine the depth of a gamma-ray interaction point over the full active volume of a thick germanium strip detector. This capability provides depth resolution of less than 0.5-mm full width half maximum (FWHM) at 122 keV in a device 11 mm thick with a 2-mm strip pitch. Fifty channels of electronics have been developed and tested with a 25 × 25 germanium orthogonal strip detectors. Experiments examining the capabilities of the system and demonstrating a simple Compton telescope using a single detector have been performed.
Keywords
bubble chambers; gamma-ray detection; germanium radiation detectors; 11 mm; 122 keV; Compton telescope; FWHM; Ge strip detector; depth; full width half maximum; gamma-ray interaction point; Charge carrier processes; Electronic equipment testing; Energy resolution; Face detection; Gamma ray detection; Gamma ray detectors; Germanium; Strips; Time measurement; Timing;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.2002.801526
Filename
1043566
Link To Document