• DocumentCode
    852247
  • Title

    A Gas Ionization Sampling Electromagnetic Shower Detector

  • Author

    Atac, M. ; Hanssen, D. ; Jensen, H. ; Tollestrup, A. ; Urish, J. ; Kennett, R.G. ; Walker, R. ; Nodulman, L.

  • Author_Institution
    Fermi National Accelerator Laboratory, Batavia, IL 60510
  • Volume
    28
  • Issue
    1
  • fYear
    1981
  • Firstpage
    500
  • Lastpage
    505
  • Abstract
    The results of the tests of a prototype ionization sampling calorimeter are presented. Using proportional chmbers interleaved with lead and sampling every 0.68 radiation length, we found an energy resolution of 24%/¿E. Measurements of position resolution, lateral shower developent, and hadron rejection are discussed.
  • Keywords
    Circuits; Foot; Gain measurement; Hydrogen; Ionization; Magnetic analysis; Monitoring; Pulse amplifiers; Sampling methods; Wires;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1981.4331227
  • Filename